Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Eur Heart J ; 43(33): 3100-3114, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35580836

ABSTRACT

AIM: To assess the effects of 1- or ≥3-month dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients who received biodegradable-polymer sirolimus-eluting stents for complex percutaneous coronary intervention (PCI) and/or acute coronary syndrome (ACS). METHODS AND RESULTS: In the MASTER DAPT trial, 3383 patients underwent non-complex (abbreviated DAPT, n = 1707; standard DAPT, n = 1676) and 1196 complex (abbreviated DAPT, n = 588; standard DAPT, n = 608) PCI. Co-primary outcomes at 335 days were net adverse clinical events [NACE; composite of all-cause death, myocardial infarction, stroke, and bleeding academic research consortium (BARC) 3 or 5 bleeding events]; major adverse cardiac or cerebral events (MACCE; all-cause death, myocardial infarction, and stroke); and Types 2, 3, or 5 BARC bleeding. Net adverse clinical events and MACCE did not differ with abbreviated vs. standard DAPT among patients with complex [hazard ratio (HR): 1.03, 95% confidence interval (CI): 0.69-1.52, and HR: 1.24, 95% CI: 0.79-1.92, respectively] and non-complex PCI (HR: 0.90, 95% CI: 0.71-1.15, and HR: 0.91, 95% CI: 0.69-1.21; Pinteraction = 0.60 and 0.26, respectively). BARC 2, 3, or 5 was reduced with abbreviated DAPT in patients with and without complex PCI (HR: 0.64; 95% CI: 0.42-0.98, and HR: 0.70; 95% CI: 0.55-0.89; Pinteraction = 0.72). Among the 2816 patients with complex PCI and/or ACS, NACE and MACCE did not differ and BARC 2, 3, or 5 was lower with abbreviated DAPT. CONCLUSION: In HBR patients free from recurrent ischaemic events at 1 month, DAPT discontinuation was associated with similar NACE and MACCE and lower bleeding rates compared with standard DAPT, regardless of PCI or patient complexity. CLINICAL TRIAL REGISTRATION: This trial is registered with ClinicalTrials.gov, number NCT03023020, and is closed to new participants, with follow-up completed.


Subject(s)
Acute Coronary Syndrome , Myocardial Infarction , Percutaneous Coronary Intervention , Stroke , Acute Coronary Syndrome/drug therapy , Aspirin/adverse effects , Drug Therapy, Combination , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Humans , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/methods , Platelet Aggregation Inhibitors/adverse effects , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Treatment Outcome
2.
Catheter Cardiovasc Interv ; 99(2): 381-390, 2022 02.
Article in English | MEDLINE | ID: mdl-34061443

ABSTRACT

AIM: To evaluate healing response at strut-level and cross-section level after implanting an ultra-thin strut, everolimus-eluting stent with biodegradable polymer (Tetrilimus) using optical coherence tomography (OCT) at 3 and 6 months. METHODS: This was prospective, multi-centre, single-arm, and investigator-initiated study performed at seven Indian sites between January, 2017 and September, 2018. OCT evaluations were performed in 57 patients who underwent Tetrilimus stent implantation. Follow-up OCT was scheduled at 3 months for first 16 patients and at 6 months for 41 patients. Primary outcomes included degree of strut coverage, malapposition and thickness of neointimal hyperplasia (NIH) over covered struts. RESULTS: Sixty one Tetrilimus stents were implanted to treat 59 lesions in 57 patients. Paired (baseline and follow-up) OCT data was available for 12 patients and 30 patients at 3 and 6 months, respectively. At 3 months, rapid early healing was indicated by 95.48% covered struts per lesion with very low (0.11 ± 0.06 mm) NIH. At 6 months, NIH accumulation was greater (0.21 ± 0.07 mm) as compared to 3 months. 99.77% of struts per lesion were covered at 6 months. There was a very symmetrical healing as shown by very low eccentricity index. There was no difference in vascular healing between stents with small to moderate size vessels (≤3.00 mm) and large size vessels (>3.00 mm). CONCLUSION: Present study demonstrated nearly complete endothelization and low NIH accumulation at 3 and 6 months following implantation of ultra-thin strut everolimus-eluting biodegradable polymer-coated Tetrilimus stent. Moreover, though being an ultra-thin strut stent, there was no difference in vascular healing and eccentricity after implantation of the Tetrilimus stents with smaller and larger diameters.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/etiology , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Everolimus/adverse effects , Humans , Neointima/etiology , Neointima/pathology , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Sirolimus , Stents , Tomography, Optical Coherence , Treatment Outcome
3.
Catheter. cardiovasc. interv ; 98(7): 1335-1342, Dec. 2021. ilus, graf, tab
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1352807

ABSTRACT

ABSTRACT AIMS: The aim of SiBi study was to evaluate the early vascular healing and neointimal coverage after implantation of ultrathin (60 µm) biodegradable polymer-coated Tetriflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stent (SES) using optical coherence tomography (OCT) at 4 to 6 weeks after implantation. METHODS: SiBi was a single-center, observational, investigator-initiated study. From January 15, 2018 to April 15, 2018, total 29 consecutive patients who had consented and underwent OCT examination at 4­6 weeks after Tetriflex SES implantation were enrolled. All OCT images were analyzed at an independent core laboratory by analysts who were blinded to patient and procedural information. RESULTS: Of 29 patients, four patients were excluded, as those OCT images were technically inadequate for analysis. Therefore, 25 patients were included in final OCT analysis. Average OCT analysis was performed after 35.3 ± 5 days of Tetriflex implantation. Total 14,024 stent struts in 1,520 cross sections were analyzed. Strut tissue coverage was observed in 91.26 ± 5.53% of struts and malapposed struts were seen in 0.89 ± 1.67%. The mean neointimal hyperplasia (NIH) thickness on the covered struts was 50 ± 30 µm. CONCLUSION: A large percentage of struts were found to be covered with thin layer of NIH evenly distributed along the stent length at around 1 month from stent implantation. The results of this pilot study serve as ethical and scientific backbone to conduct an adequately powered clinical trial to evaluate outcomes of short dual-antiplatelet therapy in context of ultrathin strut stent.


Subject(s)
Stents , Sirolimus , Tomography, Optical Coherence
4.
Catheter Cardiovasc Interv ; 97(3): 423-430, 2021 02 15.
Article in English | MEDLINE | ID: mdl-32243050

ABSTRACT

AIM: The TAXCO study was designed to compare the degree of neointimal coverage and the prevalence of malapposition at 6 months subsequent to implantation of ultrathin biodegradable polymer-coated sirolimus-eluting stents (SES) and durable polymer-coated everolimus-eluting stents (EES) of thin strut thickness using optical coherence tomography (OCT). METHODS: The TAXCO study included a total of 42 patients who gave consent and underwent OCT examination between August 2017 and September 2017. Of 42, five patients' OCT examinations were of insufficient quality for quantitative analysis. Thus, the OCT analysis group consisted of 37 patients. Among them, 16 patients were treated with Xience (Abbott Vascular) and 21 with Tetriflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India), 6 (±1) months earlier at our institution. The OCT was performed using a C7 Dragonfly™ imaging catheter (St. Jude Medical Inc.). All OCT images were analyzed at an independent core laboratory (Cardiovascular Research Center, São Paulo, Brazil) by analysts who were blinded to patient and procedural information. RESULTS: A total of 763 crosssections (6,882 struts) were analyzed in Xience group, and 1,127 crosssections (9,968 struts) in Tetriflex group. At 6 months, on per-lesion basis, no significant differences were observed between Xience group and Tetriflex group in mean percentage of uncovered struts (1.87 ± 3.86 vs. 2.42 ± 3.46, p = .137) and malapposed struts (0.05 ± 0.2 vs. 0.21 ± 0.69, p = .302). Strut-level neointimal thickness also did not differ between Xience group and Tetriflex group (0.18 ± 0.12 vs. 0.14 ± 0.08 mm, p = .286). CONCLUSION: This OCT study found no significant difference in strut coverage and neointimal thickness at 6 months after implantation of biodegradable polymer-coated Tetriflex, when compared with durable polymer-coated Xience.


Subject(s)
Drug-Eluting Stents , Odonata , Percutaneous Coronary Intervention , Absorbable Implants , Animals , Everolimus , Follow-Up Studies , Humans , Neointima , Percutaneous Coronary Intervention/adverse effects , Polymers , Sirolimus , Stents , Tomography, Optical Coherence , Treatment Outcome
5.
Catheter Cardiovasc Interv ; 98(7): 1335-1342, 2021 12 01.
Article in English | MEDLINE | ID: mdl-33247618

ABSTRACT

AIMS: The aim of SiBi study was to evaluate the early vascular healing and neointimal coverage after implantation of ultrathin (60 µm) biodegradable polymer-coated Tetriflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stent (SES) using optical coherence tomography (OCT) at 4 to 6 weeks after implantation. METHODS: SiBi was a single-center, observational, investigator-initiated study. From January 15, 2018 to April 15, 2018, total 29 consecutive patients who had consented and underwent OCT examination at 4-6 weeks after Tetriflex SES implantation were enrolled. All OCT images were analyzed at an independent core laboratory by analysts who were blinded to patient and procedural information. RESULTS: Of 29 patients, four patients were excluded, as those OCT images were technically inadequate for analysis. Therefore, 25 patients were included in final OCT analysis. Average OCT analysis was performed after 35.3 ± 5 days of Tetriflex implantation. Total 14,024 stent struts in 1,520 cross sections were analyzed. Strut tissue coverage was observed in 91.26 ± 5.53% of struts and malapposed struts were seen in 0.89 ± 1.67%. The mean neointimal hyperplasia (NIH) thickness on the covered struts was 50 ± 30 µm. CONCLUSION: A large percentage of struts were found to be covered with thin layer of NIH evenly distributed along the stent length at around 1 month from stent implantation. The results of this pilot study serve as ethical and scientific backbone to conduct an adequately powered clinical trial to evaluate outcomes of short dual-antiplatelet therapy in context of ultrathin strut stent.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Humans , Neointima , Pilot Projects , Polymers , Sirolimus , Stents , Tomography, Optical Coherence , Treatment Outcome
6.
Indian Heart J ; 71(2): 149-154, 2019.
Article in English | MEDLINE | ID: mdl-31280828

ABSTRACT

AIM: The purpose of the present study was to examine whether clinical differences exist between the biodegradable polymer (BDP)-coated Tetrilimus everolimus-eluting stent (EES) and the durable polymer (DP)-coated Xience EES by comparing the major adverse cardiac event (MACE) rate at 12 months in all-comer patients. METHODS: This study was designed as a multicentre, observational, retrospective, investigator-initiated study between January 2016 and October 2016. Two hundred thirteen patients who underwent percutaneous coronary intervention (PCI) with the BDP-EES were compared with 204 patients who underwent PCI with the DP-EES, irrespective of lesion complexity, comorbidities and acute presentation. The primary end point was MACE defined as a composite of cardiac death, myocardial infarction and target lesion revascularization. RESULTS: Baseline clinical and lesion characteristics of both the groups were similar, although the BDP-EES group had a significantly higher number of patients with diabetes mellitus (39.9% vs. 30.4%; p = 0.042) and type C lesion (67.4% vs. 48.1%; p < 0.001) than the DP-EES group. The 12-month MACE rate was 4.2% for the BDP-EES group versus 4.9% for the DP-EES group (p = 0.740). Mortality was lower in the BDP-EES group than in the DP-EES group (0.9% vs. 2.0%; p = 0.441). CONCLUSION: The present comparative analysis shows that the BDP-coated Tetrilimus EES was as safe and effective as the DP-coated Xience EES during the 12-month follow-up period despite complex lesion characteristics.


Subject(s)
Coronary Disease/drug therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Immunosuppressive Agents/administration & dosage , Absorbable Implants , Coated Materials, Biocompatible , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention , Polymers , Prosthesis Design , Retrospective Studies , Treatment Outcome
7.
Indian Heart J ; 70 Suppl 3: S280-S284, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30595275

ABSTRACT

OBJECTIVE: The aim of the present study was to assess seven-year clinical outcomes of biodegradable polymer coated Supralimus sirolimus-eluting stent (S-SES) [Sahajanand Medical Technologies Pvt. Ltd., Surat, India] in real-world patients with coronary artery disease. METHODS: This observational, retrospective study was carried out in all 346 consecutive enrolled patients who underwent percutaneous coronary intervention (PCI) with the S-SES, between April 2008 and December 2009, at a single center. We analyzed major adverse cardiac events (MACE) [a composite of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR) and target vessel revascularization (TVR)] as primary outcomes at seven-year follow-up. RESULTS: Out of 346 patients, seven-year follow-up was obtained in 327 (94.5%) patients and hence results were analyzed for 327 patients. At seven-year, MACE occurred in 41 (12.5%) patients, consisting of 23 (7.0%) cardiac deaths, 14 (4.3%) TLR, and 4 (1.2%) TVR. The incidence of late stent thrombosis was observed in 3 (0.9%) patients. At follow-up of seven-year, the cumulative event-free survival was found to be 84.7% by Kaplan-Meier method. CONCLUSIONS: The present study demonstrated satisfactory and sustained seven-year clinical outcomes as evidenced by the low rates of MACE and ST for the biodegradable polymer coated S-SES.


Subject(s)
Absorbable Implants , Coronary Artery Disease/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/methods , Polymers , Sirolimus/pharmacology , Female , Follow-Up Studies , Humans , Immunosuppressive Agents/pharmacology , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Time Factors , Treatment Outcome
8.
BMJ Open ; 6(2): e010028, 2016 Feb 17.
Article in English | MEDLINE | ID: mdl-26888727

ABSTRACT

OBJECTIVES: To evaluate, in the FLEX Registry, clinical outcomes of an ultrathin (60 µm) biodegradable polymer-coated Supraflex sirolimus-eluting stent (SES) for the treatment of coronary artery disease. Additionally, to determine the vascular response to the Supraflex SES through optical coherence tomography (OCT) analysis. SETTING: Multicentre, single-arm, all-comers, observational registry of patients who were treated with the Supraflex SES, between July 2013 and May 2014, at nine different centres in India. PARTICIPANTS: 995 patients (1242 lesions) who were treated with the Supraflex SES, between July 2013 and May 2014, at nine different centres in India. A total of 47 participants underwent OCT analysis at 6 months' follow-up. INTERVENTIONS: Percutaneous coronary intervention with Supraflex SES, PRIMARY AND SECONDARY OUTCOME MEASURES: The primary endpoint-the rate of major adverse cardiac events (defined as a composite of cardiac death, myocardial infarction (MI), target lesion revascularisation (TLR))-was analysed during 12 months. RESULTS: At 12 months, the primary endpoint occurred in 36 (3.7%) of 980 patients, consisting of 18 (1.8%) cardiac deaths, 16 (1.6%) MI, 7 (0.7%) TLR and 2 (0.2%) cases of non-target lesion target vessel revascularization. In a subset of 47 patients, 1227 cross-sections (9309 struts) were analysed at 6 months by OCT. Overall, a high percentage of struts was covered (98.1%), with a mean neointimal thickness of 0.13 ± 0.06 µm. CONCLUSIONS: The FLEX Registry evaluated clinical outcomes in real-world and more complex cohorts and thus provides evidence that the Supraflex SEX can be used safely and routinely in a broader percutaneous coronary intervention population. Also, the Supraflex SES showed high percentage of stent strut coverage and good stent apposition during OCT follow-up.


Subject(s)
Antibiotics, Antineoplastic/administration & dosage , Coronary Artery Disease/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention , Registries , Sirolimus/administration & dosage , Absorbable Implants , Aged , Cardiovascular Diseases/mortality , Female , Humans , India , Male , Middle Aged , Myocardial Infarction/epidemiology , Myocardial Revascularization/statistics & numerical data , Neointima/pathology , Polymers , Tomography, Optical Coherence
9.
Article in English | MEDLINE | ID: mdl-26585397

ABSTRACT

BACKGROUND: Drug-eluting stents (DES) have been shown to reduce the rate of acute complications and the need for subsequent revascularization in cases where single-vessels are treated. The performance of DES in patients with multivessel disease and complex lesions, however, remains controversial. This study assessed and compared clinical outcomes following single vs. multivessel percutaneous coronary intervention (PCI), using the Supraflex sirolimus-eluting stent (SES), in an all-comers patient population. METHODS: We conducted retrospective, multicenter, all-comers, observational study of 995 patients, who underwent either single-vessel PCI (n=769 patients; group-I) or multivessel PCI (n=226 patients; group-II), treated with the biodegradable polymer coated Supraflex SES, between July-2013 and May-2014 at nine different centers in India. Pre-specified primary endpoint, rate of major adverse cardiac events (MACE) [defined as composite of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR) and non-target lesion target vessel revascularization (non-TL TVR)], was analyzed during 12 months after the post-index procedure. We also analyzed the incidence of stent thrombosis (ST) as a safety endpoint during the follow-up period, as defined by the Academic Research Consortium (ARC). RESULTS: Of the whole study group, 1,242 lesions were treated in 995 patients (mean age 61.6±10.8 years; 80.0% male) with average stent length of 26.8±9.3 mm. Multivessel PCI patients were older, had a higher prevalence of arterial hypertension, were smoker, had a family history of coronary artery disease, previous stroke and previous PCI compared to single-vessel PCI patients. Follow-up was available in 99.0% (761/769) of patients with single-vessel intervention and 96.9% (219/226) of patients with multivessel intervention at the end of 12 months. In-hospital MACE was similar for both the groups [group-I, 3 (0.4%) vs. group-II, 1 (0.4%); p=1.000]. The observed MACE for group-I and group-II, at 30 days, 6 and 12 months follow-up were 9 (1.2%) vs. 2 (0.9%); p=1.000, 15 (2.0%) vs. 7 (3.2%); p=0.302 and 24 (3.2%) vs. 12 (5.5%); p=0.109, respectively. The cumulative incidence curves for MACE showed no significant differences between the two groups, at the end of 12 months (p=0.109). CONCLUSION: Our study shows that use of the Supraflex SES in single and multivessel coronary artery disease produces good clinical outcomes during 12 months of follow-up with a low rate of revascularization, despite complex lesion morphology.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Coronary Artery Disease/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/methods , Sirolimus/therapeutic use , Aged , Anti-Bacterial Agents/administration & dosage , Drug-Eluting Stents/adverse effects , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Retrospective Studies , Sirolimus/administration & dosage , Thrombosis/etiology , Treatment Outcome
10.
N Engl J Med ; 373(18): 1709-19, 2015 Oct 29.
Article in English | MEDLINE | ID: mdl-26466202

ABSTRACT

BACKGROUND: The choice of drug-eluting stent in the treatment of patients with diabetes mellitus and coronary artery disease who are undergoing percutaneous coronary intervention (PCI) has been debated. Previous studies comparing paclitaxel-eluting stents with stents eluting rapamycin (now called sirolimus) or its analogues (everolimus or zotarolimus) have produced contradictory results, ranging from equivalence between stent types to superiority of everolimus-eluting stents. METHODS: We randomly assigned 1830 patients with diabetes mellitus and coronary artery disease who were undergoing PCI to receive either a paclitaxel-eluting stent or an everolimus-eluting stent. We used a noninferiority trial design with a noninferiority margin of 4 percentage points for the upper boundary of the 95% confidence interval of the risk difference. The primary end point was target-vessel failure, which was defined as a composite of cardiac death, target-vessel myocardial infarction, or ischemia-driven target-vessel revascularization at the 1-year follow-up. RESULTS: At 1 year, paclitaxel-eluting stents did not meet the criterion for noninferiority to everolimus-eluting stents with respect to the primary end point (rate of target-vessel failure, 5.6% vs. 2.9%; risk difference, 2.7 percentage points [95% confidence interval, 0.8 to 4.5]; relative risk, 1.89 [95% confidence interval, 1.20 to 2.99]; P=0.38 for noninferiority). There was a significantly higher 1-year rate in the paclitaxel-eluting stent group than in the everolimus-eluting stent group of target-vessel failure (P=0.005), spontaneous myocardial infarction (3.2% vs. 1.2%, P=0.004), stent thrombosis (2.1% vs. 0.4%, P=0.002), target-vessel revascularization (3.4% vs. 1.2%, P=0.002), and target-lesion revascularization (3.4% vs. 1.2%, P=0.002). CONCLUSIONS: In patients with diabetes mellitus and coronary artery disease undergoing PCI, paclitaxel-eluting stents were not shown to be noninferior to everolimus-eluting stents, and they resulted in higher rates of target-vessel failure, myocardial infarction, stent thrombosis, and target-vessel revascularization at 1 year. (Funded by Boston Scientific; TUXEDO-India Clinical Trials Registry-India number, CTRI/2011/06/001830).


Subject(s)
Coronary Artery Disease/therapy , Diabetes Complications/therapy , Drug-Eluting Stents , Paclitaxel/administration & dosage , Percutaneous Coronary Intervention , Sirolimus/analogs & derivatives , Aged , Coronary Angiography , Coronary Artery Disease/complications , Coronary Artery Disease/mortality , Everolimus , Female , Humans , Intention to Treat Analysis , Logistic Models , Male , Middle Aged , Retreatment/statistics & numerical data , Sirolimus/administration & dosage , Treatment Outcome
11.
World J Cardiol ; 5(4): 112-4, 2013 Apr 26.
Article in English | MEDLINE | ID: mdl-23675559

ABSTRACT

Kounis syndrome is defined as the coexistence of acute coronary syndromes with situations associated with allergy or hypersensitivity, as well as anaphylactic or anaphylactoid reactions, to a variety of medical conditions, environmental and medication exposures. We report a case of Kounis-Zavras syndrome type I variant in the setting of aspirin-induced asthma, or the Samter-Beer triad of asthma, nasal polyps and aspirin allergy. When there is a young individual with no predisposing factors of atherosclerosis and apparent coronary lesion, with or without electrocardiography and biochemical markers of infarction, the possibility of Kounis syndrome should be kept in mind.

12.
Indian Heart J ; 64(6): 541-6, 2012.
Article in English | MEDLINE | ID: mdl-23253404

ABSTRACT

INTRODUCTION: Immediate and acute stent recoil has been observed following balloon deflation in normal and diseased coronary arteries, and the degree varies by stent design. METHODS: A total of 19 patients, who underwent elective stent implantation for single de novo native coronary artery lesions, were enrolled: all patients treated with the biodegradable polymer-coated sirolimus-eluting cobalt-chromium coronary stent system (Supralimus-Core(®)). The immediate, acute and cumulative stent recoil was assessed by quantitative coronary angiography. The cumulative stent recoil was measured at 24 h of stent implantation. RESULTS: The absolute late loss due to recoil was found 0.08 ± 0.19 mm for Immediate Stent Recoil (ISR), 0.05 ± 0.21 mm for Acute Stent Recoil (ASR) and 0.11 ± 0.25 mm for Cumulative Stent Recoil (CSR) respectively. CONCLUSIONS: In vivo acute stent recoil of the Supralimus-Core(®) has higher radial strength compared to other available standard drug-eluting stents.


Subject(s)
Coronary Artery Disease/therapy , Drug-Eluting Stents , Immunosuppressive Agents/administration & dosage , Sirolimus/administration & dosage , Absorbable Implants , Chromium , Coated Materials, Biocompatible , Cobalt , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Drug-Eluting Stents/adverse effects , Female , Humans , Male , Middle Aged , Polymers , Prospective Studies , Risk Factors , Treatment Outcome
13.
Indian Heart J ; 64(3): 273-9, 2012.
Article in English | MEDLINE | ID: mdl-22664810

ABSTRACT

OBJECTIVES: This study was conducted to assess the systemic drug release and distribution of sirolimus-eluting coronary stents. METHODS: Twenty patients with coronary artery disease (CAD) were treated with 1, 2, or 3 a newly designed metallic stents. Blood samples were drawn at 14 time points to determine the pharmacokinetic of sirolimus. Whole blood concentrations of sirolimus were determined by using a sensitive validated high-performance liquid chromatography mass spectrometry/mass spectrometry method. RESULTS: Minimal measurable blood levels were detectable at 7 days. Across all dose levels, individual T(max) values ranged from 1.00 hour and 12.00 hours; individual C(max) ranged from 0.73 ng/mL and 4.13 ng/mL. CONCLUSION: This study confirms the limited exposure of the systemic circulation of the eluted drug with the use of the Supralimus-Core® Sirolimus-Eluting Coronary Stent System (Sahajanand Medical Technologies Pvt. Ltd., Surat, India). In this study, sirolimus concentration in systemic circulation is to be safe, well-tolerated and short-lived.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease/metabolism , Coronary Artery Disease/therapy , Drug-Eluting Stents , Immunosuppressive Agents/pharmacokinetics , Sirolimus/pharmacokinetics , Adult , Female , Humans , India , Male , Middle Aged , Treatment Outcome
14.
Indian Heart J ; 60(1): 39-44, 2008.
Article in English | MEDLINE | ID: mdl-19212020

ABSTRACT

OBJECTIVE: Outcomes of primary angioplasty can be improved by achieving better pre/post PCI TIMI flows. Earlier administration of antithrombotic and antiplatelet agents may help in achieving better TIMI flows. We evaluated the role of intravenous bolus of enoxaparin administered immediately after the diagnosis of STEMI in the emergency room. METHODOLOGY: We compared the data of 100 consecutive patients in the emergency room, administered intravenous enoxaparin immediately after the diagnosis of STEMI (within 12 hours from the onset of pain). The patients had undergone primary PCI with 100 patients receiving unfractionated heparin administered during primary PCI. All patients received 325 mg Aspirin, 300 mg Clopidogrel on admission and platelet IIb/IIIa antagonist during and after PCI. Enoxaparin group received 0.6 ml IV enoxaparin (0.8 ml if weight > 80 kg). TIMI flows on pre/post PCI angiograms were studied. Clinical end points included death and MACE rates at 30 days. RESULTS: Both the groups were demographically similar. Pre PCI TIMI 2/3 flow increased from 18%-24% (p = 0.385). TIMI 3 flow increased from 8%-17% (p = 0.087). Post PCI TIMI 3 flow increased from 91%-96% (p = 0.251). There was absolute improvement of 9% in pre PCI TIMI 3 flow and 5% in post PCI TIMI 3 flow. There was no significant difference in the mortality and MACE rates at 30 days. CONCLUSION: Enoxaparin administered early in the emergency room after the diagnosis of STEMI improved pre and post PCI TIMI 3 flows with an absolute improvement of 9% in pre PCI TIMI 3 flow. Death and MACE rates showed trends towards improvement although they were not statistically significant.


Subject(s)
Angioplasty, Balloon, Coronary , Anticoagulants/therapeutic use , Emergency Service, Hospital , Enoxaparin/therapeutic use , Myocardial Infarction/therapy , Adult , Anticoagulants/administration & dosage , Cohort Studies , Drug Administration Schedule , Enoxaparin/administration & dosage , Female , Humans , Male , Middle Aged , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...